Ceiling Light Sensor With Corridor Function, PWM Dimming And Remote Control Available
| Menşe yeri | Shenzhen, Çin |
|---|---|
| Marka adı | Merrytek |
| Sertifika | CE , RED |
| Model numarası | MC137D B |
| Min sipariş miktarı | 100 adet |
| Fiyat | Anlaşılabilir |
| Ambalaj bilgileri | Balonlu torba + bölme + dış kutu (K=A) |
| Teslim süresi | <i>1, Sample and small order: Within 5 working days after receiving your payment.</i> <b>1, Örnek ve |
| Ödeme koşulları | T/T |
| Yetenek temini | 10000 PC/Ay |
Ücretsiz numuneler ve kuponlar için bana ulaşın.
Naber:0086 18588475571
WeChat: 0086 18588475571
Skype: sales10@aixton.com
Herhangi bir endişeniz varsa, 24 saat çevrimiçi yardım sağlıyoruz.
x| Nominal Gerilim | 12 ± 0,5VDC | Çalışma akımı | 16±2mA |
|---|---|---|---|
| Çıkış Sinyali | PWM karartma sinyali | Çalışma frekansı | 5.8GHz ±75MHz, ISM bandı |
| Kurulum Yüksekliği | 3m (max 6m) | Ömür boyu | 5 yıl garanti@ta |
| Vurgulamak | dimmable motion sensor ceiling light,corridor function ceiling light sensor,PWM dimming remote control light |
||
Advanced ceiling light sensor featuring corridor function, PWM dimming capability, and optional remote control for comprehensive lighting management.
- Patented Miniature Coupled Pole Antenna
- Long strip shell with miniature antenna design, no shading
- Ultra-low RF power output, harmless to human health
- Support remote control and DIP switch for parameter adjustment
- Low side wave with high adaptability to metal environments
- Unaffected by temperature, humidity, noise, airflow, dust, and light conditions
| Function | Available |
|---|---|
| Switch function | ○ |
| Two stage dimming function | √ |
| Three-stage dimming function | √ |
| Daylight harvesting | ○ |
| Daylight priority function | ○ |
Remote Control Available for Option
The sensor will turn on the light at 100% brightness for the first time, and turn it off after 10 seconds. During the initialization period, sensor is not able to detect movement.
- Sensitivity: 100%
- Hold Time: 5 s
- Daylight Threshold: Disable
- Stand-by period: +∞
- Stand-by Dim level: 10%
The sensor should be installed by a professional electrician. Please cut off the power before installing, wiring, changing the setting of the dial switch, etc.
The sensing distance is related to factors such as the moving speed of the moving object, the size of the moving object, the installation height, the installation angle, whether the installation environment is open, and the material of the reflector. The detection distance given in the specification is a typical value, which is 165cm/65kg tester, and it is tested in an open indoor environment.
When the microwave sensor is installed on the wall, the detection distance will be greatly increased compared with that installed on the ceiling. If you use the wall installation method, please reduce the sensitivity to use or contact our company to confirm the use setting. The light sensitivity threshold is in a sunny environment, no shadows, and ambient light diffuse reflection conditions. In different time periods, climates, and environments, the illuminance value detected by the light sensor may be different.
Sensor parameters may need to be reconfigured in different installation environments, please refer to the following instructions or contact the manufacturer.
This sensor is only for indoor use, outdoor wind and rain, and surrounding moving objects will cause false triggering.
The installation height of the sensor product cannot exceed 6 meters, and the optimal height is 3 meters; the distance between the two sensors should be greater than 3 meters.
When the sensor is installed in a metal lamp, on a metal reflective surface, or in a narrow closed environment, microwaves will be reflected multiple times and cause false triggering. Please reduce the sensor sensitivity or contact the manufacturer for technical support.
Please make sure that there are no moving signals such as fans, DC motors, sewer pipes, air outlets, etc. around the sensor, otherwise the sensor may cause false triggering.
Microwaves cannot penetrate metal, avoid installing in closed or semi-closed metal lamps, and there should be no metal or glass blocking the product.
Sensor with different PWM / 0-10V driver, low light effect may be different.
A DC regulated power supply with stable output voltage and low ripple coefficient must be used. The ripple of the power supply should be less than 100mV; the load current should be greater than 35 mA.
Product specifications and parameters may be optimized without prior notice.